Grenkago ENFRAR
Home / Hybrid Inverters

Hybrid Solar Inverters — HE200 & HE300 Series

One line: Hybrid inverters that run off-grid, grid-connected or in mixed mode — including battery-free operation and dual AC output by load priority. 1.2 kW to 11 kW per unit, up to 99 kW paralleled.
Grenkago solar inverter range on a light background, six models labelled with name and power rating
Six of the models we supply — off-grid from 1.2 kW through to the 6.5 kW hybrid, with the documents to match.
Pair of hybrid solar inverters shown front and three-quarter side by side
Hybrid range — mains, generator and PV input on every model.

Model range

Every figure below is taken from the manufacturer's specification sheets. Where the model number digit differs from the actual rated output, the rated output column is the one that matters.

ModelRated outputBattery voltageMax PV inputProtectionNet weight
HE200-3000-O-I52000 W12 V3000 WIP546.5 kg
HE200-4200-T3600 W24 V5000 WIP216.5 kg
HE200-4200-T-I53600 W24 V5000 WIP548.65 kg
HE200-6500-T5500 W24 V9000 WIP218.6 kg
HE200-7200-F6200 W48 V9000 WIP218.2 kg
HE200-7200-F-I56200 W48 V9000 WIP5411.7 kg
HE200-12000-F12000 W48 V2 × 7500 WIP2115.15 kg
HE300-7200-F6200 W48 V8500 WIP219.7 kg
HE300-12000-F11000 W48 V2 × 7500 WIP2121 kg
HE300-12000-F-I511000 W48 V2 × 7500 WIP5422.9 kg
HE200-7200-FP58500 W (9 units)48 V9000 W / stringIP218.7 kg
HE300-7200-FP-I555800 W (9 units)48 V8500 W / unitIP5414.75 kg
HE300-12000-FP99000 W (9 units)48 V7500 W / stringIP2121.3 kg
Read the number carefully. A 7200 model is a 6200 W machine; a 12000 gets you 12000 W on HE200 but 11000 W on HE300. See the model number decoder for the full mapping.

What "hybrid" means here

These units can operate in three modes and switch between them:

Output is a pure sine wave, so inductive loads (motors, pumps, compressors) start without the buzzing and heating that modified-sine units cause.

Core features

Battery-free operation. A hybrid model can run with PV and grid only, with no battery connected. Buyers can start without the cost of a battery bank and add storage later without replacing the inverter.

Dual AC output by priority. From the HE200-6500-T upward, models use an L1+N1+L2+N2+PE topology — a main output and a secondary output. Wire critical loads to the main output and non-critical loads to the secondary. When battery charge runs low, the unit drops the secondary output to extend runtime on the main output. This is the feature contractors value most on backup projects.

Parallel expansion. Models with an FP suffix parallel up to 9 units, delivering either 415 Vac three-phase or single-phase expansion — 58.5 kW on HE200-7200-FP, 99 kW on HE300-12000-FP.

IP54 variants. Models with the I5 suffix use a sealed enclosure rated IP54 for outdoor installation. Note that these are separate models: an IP54 certificate or specification does not carry over from the IP21 version.

BMS communication. CAN and RS485 ports connect to lithium battery BMS units from Pylontech, Growatt, SRNE, Deye, Voltronic and others. Where communication fails, the unit can be set to manual charge/discharge voltages.

Monitoring. Wi-Fi module plugs into the COM port; the app and cloud platform show generation data, faults and support OTA updates.

Internal power board of a hybrid inverter showing the MPPT and inverter stages
Inside a hybrid unit — MPPT stage, inverter stage and control board.

Single-phase output range

All listed hybrid models provide 230/240 Vac single-phase output at 50/60 Hz, with an input range of 90–280 Vac. Parallel models can additionally provide 415 Vac three-phase output.

Which model for which job

SituationSuggested models
Small home, light backup, lowest entry costHE200-3000-O-I5 (IP54, no-battery capable)
Standard home with 5–6 kW of PVHE200-6500-T or HE200-7200-F
Home with critical-load separationHE200-7200-F (dual AC output)
Large home or small commercial, high PVHE200-12000-F or HE300-12000-F
Three-phase commercial siteHE200-7200-FP / HE300-12000-FP (9-unit parallel)