Grenkago ENFRAR
Home / HE200-7200-F

HE200-7200-F — 6200 W Hybrid Inverter, 48 V

One line: The best-documented model in the range and the natural 48 V choice — 6200 W output, 9000 W PV input, dual AC output, full certification coverage.
HE200-7200-F 6200 W 48 V hybrid solar inverter, front view with LCD panel
HE200-7200-F — the best-documented model in the range: 6,200 W output, 48 V system, dual AC output.

Specifications

CategoryItemValue
Inverter outputMaximum output power6200 W
Maximum output voltage240 Vac ±5% (single phase)
Maximum output current27 A
Output frequency50/60 Hz
Output waveformPure sine wave
Output topologyL1+N1+L2+N2+PE (dual output)
BatteryBattery typeLead-acid / lithium
Rated battery voltage48 Vdc
Max combined PV charge current120 A
Charging modesTwo-stage / three-stage / automatic
PV inputMPPT strings1
Maximum input power9000 W
Maximum open-circuit voltage500 Vdc
Maximum short-circuit current27 A
Open-circuit working range60–450 Vdc
Efficiency99.5% (PV charging)
Grid / generator inputInput voltage range90–280 Vac
Rated input voltage220 Vac
Input frequency50/60 Hz
Maximum current40 A
GeneralDimensions395 × 332.4 × 116.2 mm
Net weight8.2 kg
Gross weight9.6 kg
Protection ratingIP21
Operating temperature−10 to 50 °C (catalogue) / −10 to 60 °C (parameter table)
CoolingSmart fan cooling
Humidity5–95%
An IP54 variant, HE200-7200-F-I5, carries the same electrical specification — 6200 W, 48 V, 9000 W PV input — in a sealed enclosure at 11.7 kg: 500 × 359 × 126 mm, gross 13.35 kg. Same machine, different enclosure. On the model number: the "7200" is a machine code, not the rating. Rated output is 6200 W. One catalogue edition lists 6500 W, but the specification sheet and parameter table both give 6200 W, and we quote 6200 W consistently.

Features

Rear of the HE200-7200-F showing the main ON/OFF switch and the rating label
Rear panel — main ON/OFF switch and rating label.
Underside of the HE200-7200-F with dual cooling fans and the terminal block row
Underside — dual cooling fans and the full terminal row (AC in/out, battery, PV).

Why this model

Three reasons this is usually the recommended 48 V unit:

  1. Documentation. It is the main test article for the FCC SDoC report RKEYS250916316 and the GB 4943.1-2022 report RKEYS250917157, and it is listed on the UDEM CE certificate, the FCC certificate, the RoHS certificate and the GB 4943.1 report. No other model carries as complete a file set.
  2. 48 V system. At 6200 W a 48 V battery draws around 130 A rather than the 260 A a 24 V system would need — smaller cable, less heat, simpler installation.
  3. Dual AC output. From this class upward the model separates critical from non-critical loads and drops the secondary output on low battery.

Sizing context

9000 W of PV input against a 6200 W output. Practical panel wiring uses 540–700 W panels at 45–55 V open-circuit, strung 4–8 in series and paralleled as needed. The array working voltage must fall inside 60–450 Vdc, and the open-circuit voltage must never exceed 500 V.

Battery-side: at 6200 W and 48 V, expect around 130 A of battery current. Plan for 35–50 mm² battery cable and a 150–250 A breaker. Charge current must respect the battery chemistry — 0.2C for lead-acid, 0.5C for lithium. See the installation guide.

An idiomatic system: a house with a workshop circuit, around 12 kWh daily consumption, one day of autonomy, 4–5 kWp of PV. The main output carries the house, the secondary carries the workshop, and the house keeps running when the battery gets low.

Connections, monitoring and accessories

Terminal layout, system wiring, monitoring options and the accessories supplied with the unit.

Product operation diagram for the HE200-7200-F: PV array, grid, battery bank, loads and communication shown as one system
System layout — PV array, grid input, battery bank, backed-up loads and monitoring on one diagram.
Interface legend for the HE200-7200-F listing AC input, main and second output, battery input, PV input, PE, COM port and BMS communication port
Interface legend — AC input, main output, second output, battery input, PV input, PE, COM port and BMS communication port.
Packaging and accessories for the HE200-7200-F: carton, accessories and user manual
Package and accessories — carton, accessory kit and user manual.

Certification coverage

CertificationStatus
CE (LVD + EMC) — M.2025.206.C116069Covered (listed model)
FCC Part 15 Subpart B SDoC — CKEYS251013025Covered — and the main test article for report RKEYS250916316
RoHS 2.0 — CKEYS251013024Covered — and the main test article for report RKEYS250916315
GB 4943.1-2022 — RKEYS250917157Covered — and the main test article

This is the only model in the range where every file held is directly applicable rather than series-only.

The IP54 variant is different. HE200-7200-F-I5 is not listed in the UDEM CE certificate — that certificate covers no I5 model at all — so CE (LVD + EMC) must be treated as not held for the I5 variant. It does appear on the FCC and RoHS model lists and on both GB 4943.1-2022 reports, as series coverage. Full detail on the certifications page.

Related models

Request a quotation