HE200-12000-F — 12000 W Hybrid Inverter, Dual MPPT

One line: The largest HE200 single unit — 12000 W, dual MPPT, dual AC output, 48 V battery. Built for whole-home or light-commercial loads with two independent arrays.
HE200-12000-F 12 kW hybrid solar inverter, front view with the LCD panel and control keys
HE200-12000-F, front view — LCD panel and control keys; the model code and rating label sit on the rear.
HE200-12000-F 12 kW hybrid inverter, side view showing chassis depth and the rating label
HE200-12000-F — 12,000 W class with dual MPPT tracking.

Specifications

CategoryItemValue
Inverter outputMaximum output power12000 W
Maximum output voltage240 Vac ±5% (single phase)
Maximum output current54.5 A
Output frequency50/60 Hz
Output waveformPure sine wave
Output topologyL1+N1+L2+N2+PE (second output max 40 A)
BatteryBattery typeLead-acid / lithium
Rated battery voltage48 Vdc
Battery voltage range40–60 V
Max combined PV charge current160 A
PV inputMPPT strings2
Maximum input power2 × 7500 W (7500 W per string)
Maximum open-circuit voltage500 Vdc
Maximum short-circuit current2 × 22.5 A
Open-circuit working range60–450 Vdc
Efficiency99.5% (PV charging)
Grid / generator inputInput voltage range90–280 Vac
Rated input voltage230 Vac
Input frequency50/60 Hz
Maximum bypass current70 A
GeneralDimensions494 × 408 × 127 mm
Net weight15.15 kg
Gross weight17.4 kg
Protection ratingIP21
Operating temperature−10 to 60 °C
CoolingSmart fan cooling
Humidity5–95%
An IP54 variant, HE200-12000-F-I5, carries the same electrical specification — 12000 W, 48 V, dual MPPT — in a sealed enclosure for outdoor installation. It is a separate model: neither the protection rating nor the certification position carries over from the IP21 version.

Features

Underside of the HE200-12000-F showing dual cooling fans and the terminal row
Underside — dual fans and the full terminal row.
Rear rating label of the HE200-12000-F listing model code and electrical ratings
Rear rating label — model code and ratings.

Why dual MPPT matters

Two MPPT strings mean two PV arrays can be connected independently. If one array faces east and the other west, or one is partly shaded during part of the day, each tracks its own maximum power point. On a single-MPPT unit, both arrays would be forced to a shared operating point, and the weaker array drags the stronger one down.

For sites with roof sections in different orientations, this is often the deciding feature. Array limit is 7500 W per string, with an open-circuit working range of 60–450 Vdc and a 500 Vdc maximum.

Sizing context

With 15 kW of PV input against a 12 kW output, the array comfortably serves the load and charges the battery. Battery current at full load is around 260 A at 48 V, so battery cable and breaker rating need attention — plan for substantial cable and a 250 A-class breaker.

The dual output allows a split: main output for the house (up to 12000 W), secondary output (up to 40 A) for a workshop, outbuilding or non-critical circuit. When the battery runs low, the secondary output drops and the house keeps running.

Typical applications

Connections, monitoring and accessories

Terminal layout, system wiring, monitoring options and the accessories supplied with the unit.

Diagram showing the HE200-12000-F operating without a battery connected, taking power from the PV array
Battery-free operation — the unit can run from the PV array alone when no battery bank is fitted.
Phone showing the Wi-Fi monitoring app connected to an HE200-12000-F inverter
Optional Wi-Fi module — monitoring and parameter setting from a phone.

Certification coverage

CertificationStatus
CE (LVD + EMC) — M.2025.206.C116069Not held for this model
FCC SDoC — CKEYS251013025Covered (series)
RoHS 2.0 — CKEYS251013024Covered (series)
GB 4943.1-2022 — RKEYS250917157Covered (series)
GB 4943.1-2022 — BDL260706S002Covered (series)
This model has FCC, RoHS and safety coverage but no CE file of its own — the UDEM LVD+EMC certificate lists 14 HE200 and HE500 models and this is not one of them. Confirm before quoting CE. The IP54 variant differs again. HE200-12000-F-I5 is on the FCC and RoHS model lists and on the RKEYS250917157 safety report, but it is not in the BDL260706S002 report. Treat the two variants as separate certification cases. Full detail on the certifications page.