HE200-12000-F — 12000 W Hybrid Inverter, Dual MPPT
One line: The largest HE200 single unit — 12000 W, dual MPPT, dual AC output, 48 V battery. Built for whole-home or light-commercial loads with two independent arrays.


Specifications
| Category | Item | Value |
|---|---|---|
| Inverter output | Maximum output power | 12000 W |
| Maximum output voltage | 240 Vac ±5% (single phase) | |
| Maximum output current | 54.5 A | |
| Output frequency | 50/60 Hz | |
| Output waveform | Pure sine wave | |
| Output topology | L1+N1+L2+N2+PE (second output max 40 A) | |
| Battery | Battery type | Lead-acid / lithium |
| Rated battery voltage | 48 Vdc | |
| Battery voltage range | 40–60 V | |
| Max combined PV charge current | 160 A | |
| PV input | MPPT strings | 2 |
| Maximum input power | 2 × 7500 W (7500 W per string) | |
| Maximum open-circuit voltage | 500 Vdc | |
| Maximum short-circuit current | 2 × 22.5 A | |
| Open-circuit working range | 60–450 Vdc | |
| Efficiency | 99.5% (PV charging) | |
| Grid / generator input | Input voltage range | 90–280 Vac |
| Rated input voltage | 230 Vac | |
| Input frequency | 50/60 Hz | |
| Maximum bypass current | 70 A | |
| General | Dimensions | 494 × 408 × 127 mm |
| Net weight | 15.15 kg | |
| Gross weight | 17.4 kg | |
| Protection rating | IP21 | |
| Operating temperature | −10 to 60 °C | |
| Cooling | Smart fan cooling | |
| Humidity | 5–95% |
An IP54 variant, HE200-12000-F-I5, carries the same electrical specification — 12000 W, 48 V, dual MPPT — in a sealed enclosure for outdoor installation. It is a separate model: neither the protection rating nor the certification position carries over from the IP21 version.
Features
- Dual PV input — two independent MPPT strings.
- Battery-free operation — runs with no battery connected.
- Dual AC output — second output rated up to 40 A, for load separation by priority.
- Pure sine wave output.
- Saved battery maintenance and replacement cost, and less installation space, by comparison with a battery-dependent design.


Why dual MPPT matters
Two MPPT strings mean two PV arrays can be connected independently. If one array faces east and the other west, or one is partly shaded during part of the day, each tracks its own maximum power point. On a single-MPPT unit, both arrays would be forced to a shared operating point, and the weaker array drags the stronger one down.
For sites with roof sections in different orientations, this is often the deciding feature. Array limit is 7500 W per string, with an open-circuit working range of 60–450 Vdc and a 500 Vdc maximum.
Sizing context
With 15 kW of PV input against a 12 kW output, the array comfortably serves the load and charges the battery. Battery current at full load is around 260 A at 48 V, so battery cable and breaker rating need attention — plan for substantial cable and a 250 A-class breaker.
The dual output allows a split: main output for the house (up to 12000 W), secondary output (up to 40 A) for a workshop, outbuilding or non-critical circuit. When the battery runs low, the secondary output drops and the house keeps running.
Typical applications
- Large home with high consumption and two differently-oriented PV arrays.
- Small commercial premises needing backup and load separation.
- Light-industrial site with a mix of critical and non-critical circuits.
Connections, monitoring and accessories
Terminal layout, system wiring, monitoring options and the accessories supplied with the unit.


Certification coverage
| Certification | Status |
|---|---|
| CE (LVD + EMC) — M.2025.206.C116069 | Not held for this model |
| FCC SDoC — CKEYS251013025 | Covered (series) |
| RoHS 2.0 — CKEYS251013024 | Covered (series) |
| GB 4943.1-2022 — RKEYS250917157 | Covered (series) |
| GB 4943.1-2022 — BDL260706S002 | Covered (series) |
This model has FCC, RoHS and safety coverage but no CE file of its own — the UDEM LVD+EMC certificate lists 14 HE200 and HE500 models and this is not one of them. Confirm before quoting CE. The IP54 variant differs again. HE200-12000-F-I5 is on the FCC and RoHS model lists and on the RKEYS250917157 safety report, but it is not in the BDL260706S002 report. Treat the two variants as separate certification cases. Full detail on the certifications page.
Related models
- IP54 variant: HE200-12000-F-I5
- HE300 equivalent: HE300-12000-F — 11000 W, dual MPPT
- Hybrid inverter range