HE300-7200-F — 6200 W Hybrid Inverter, 48 V

One line: The HE300 line's mid-power 48 V unit — 6200 W output, 8500 W PV input, covered by the CE EMC certificate that specifically includes the HE300 range.
HE300-7200-F 6200 W 48 V hybrid solar inverter, front view
HE300-7200-F — 6,200 W output with APL and UPS input modes.

Specifications

CategoryItemValue
Inverter outputMaximum output power6200 W
Maximum output voltage240 Vac ±5% (single phase)
Maximum output current28.2 A
Output frequency50/60 Hz
Output waveformPure sine wave
Output topologyL+N+PE
BatteryBattery typeLead-acid / lithium
Rated battery voltage48 Vdc
Max combined PV charge current120 A
PV inputMPPT strings1
Maximum input power8500 W
Maximum open-circuit voltage500 Vdc
Maximum short-circuit current27 A
Working voltage range60–450 Vdc
Max conversion efficiency (DC/AC)98%
Grid / generator inputInput voltage range90–280 Vac ±3 V (APL) / 170–280 Vac ±3 V (UPS)
Rated input voltage230 Vac
Input frequency50/60 Hz
Maximum utility charge current100 A
GeneralDimensions402 × 315 × 120 mm
Net weight9.7 kg
Gross weight11.2 kg
Protection ratingIP21
Operating temperature−10 to 50 °C (catalogue) / −10 to 60 °C (spec sheet)
CoolingSmart fan cooling
Humidity20–95%

Two efficiency figures — do not mix them

The HE300 line publishes a 98% maximum conversion efficiency (DC/AC). This is the inverter-conversion figure, and it is a different measurement from the 99.5% PV charge efficiency quoted on the HE200 line.

Quoting "98% efficiency" without saying which stage is a common way to mislead. This page quotes each figure against its measurement.

Front three-quarter view of the HE300-7200-F
Front three-quarter view.
Side panel of the HE300-7200-F showing communication ports
Side panel — communication ports and ventilation.

APL and UPS input modes

The utility input has two voltage windows:

Setting the wrong mode for the supply condition causes nuisance transfers. Details are in the installation guide.

Sizing context

8500 W of PV input against 6200 W output. Panel wiring: 540–700 W panels at 45–55 V open-circuit, strung within the 60–450 Vdc working range, never exceeding 500 Vdc open-circuit.

Battery side: 48 V at 6200 W is around 130 A. Charge current must respect chemistry limits — 0.2C lead-acid, 0.5C lithium. The utility charge current ceiling is 100 A.

Connections, monitoring and accessories

Terminal layout, system wiring, monitoring options and the accessories supplied with the unit.

Bottom terminal row on the HE300-7200-F, showing the AC and DC connection points
Bottom terminal row on the HE300-7200-F.
Pure sine wave output waveform diagram for the HE300-7200-F
Output waveform — a pure sine wave, matching the grid waveform rather than a stepped approximation.
Product operation diagram for the HE300-7200-F: PV array, grid, battery bank, loads and communication on one diagram
System layout — PV array, grid input, battery bank, backed-up loads and monitoring on one diagram.

Certification coverage

CertificationStatus
CE (EMC) — CKEYS251201016Covered (listed model)
FCC SDoCNot held for this model
RoHS 2.0Not held for this model
GB 4943.1-2022 — BDL260706S002Covered (series)
Important: the CE file for this model covers the EMC directive only. It is not an LVD+EMC certificate like the UDEM file. If a buyer requires CE under both directives, tell us so we can state the position accurately. Full detail on the certifications page.