Grenkago ENFRAR
Home / HE310-5000-F

HE310-5000-F — 5000 W Low-Frequency Inverter

One line: An industrial-frequency inverter for the loads that punish high-frequency units — pumps, motors, compressors. 5000 W / 6300 VA, 48 V, with a no-load loss below half that of a same-power high-frequency unit.
HE310-5000-F low-frequency solar inverter, front view with LCD panel
HE310-5000-F — low-frequency design with a toroidal transformer for high-surge loads.

Specifications — input

ItemValue
Capacity6300 VA
Battery voltage (DC)48 V
Rated voltage220 VAC / 110 VAC
Voltage range154–264 VAC / 77–132 VAC
Frequency50–60 Hz auto-sensing
Input protectionCircuit breaker

Specifications — output

ItemValue
Power5000 W
Voltage220 VAC / 110 VAC
Frequency50/60 Hz
WaveformPure sine wave
Transfer time<8 ms (AC to DC) / <8 ms (DC to AC)
Efficiency>98%
Output protectionCircuit breaker

Specifications — PV and battery

ItemValue
Max PV array power6400 W (48 V)
MPPT input voltage range60–150 VDC
Max PV array open-circuit voltage150 VDC
Max solar charge current120 A
Battery typeAGM deep-cycle / GEL
Battery capacityUp to 500 Ah
Battery voltage48 VDC
Battery charging voltage54.8 VDC
Charge current50 A
Max AC charge current104 A (default 83 A) / 52 A (default 42 A)

Specifications — general

ItemValue
Transfer time≤10 ms (UPS mode) / ≤20 ms (INV mode)
Load peak ratio3:1 (max)
Standby consumption12 V: 8 W / 24 V: 16 W / 48 V: 32 W
Operating temperature−10 to 50 °C
Storage temperature−15 to 45 °C
Relative humidityup to 90%, non-condensing
Noise level<45 dB
Dimensions545 × 400 × 175 mm
Packing dimensions657 × 504 × 257 mm
Net weight26.05 kg
Gross weight28.85 kg

Why low frequency

A low-frequency inverter steps voltage through a large iron-core transformer before the output stage. The trade-off is honest:

Low-frequency (this model)High-frequency (HE200 / HE300)
Size and weightLarge, heavySmall, light
No-load lossBelow half of a same-power high-frequency unitHigher
Inductive / surge load toleranceBetterAdequate for ordinary loads
Load peak ratio3:1Model-dependent

The 3:1 peak ratio is the number that matters for motor loads: a 1.5 kW pump with a 4.5 kW starting surge sits inside this unit's capability, where a high-frequency unit of similar rating may trip.

Low no-load loss matters on systems that idle for long periods — a unit that draws less when nothing is running wastes less energy from a finite battery bank.

Features

Side view of the HE310-5000-F showing the deeper chassis required by the transformer
Side view — the deeper chassis that houses the low-frequency transformer.
Internal view of the HE310-5000-F showing the toroidal transformer and power stage
Internal view — toroidal transformer and power stage. Low-frequency topology gives the surge headroom pumps and compressors need.

Typical applications

Connections, monitoring and accessories

Terminal layout, system wiring, monitoring options and the accessories supplied with the unit.

Bottom terminal row on the HE310-5000-F, showing the AC and DC connection points
Bottom terminal row on the HE310-5000-F.
Underside of the HE310-5000-F showing the terminal layout and cable entry
Underside view — terminal layout and cable entry on the HE310-5000-F.

Certification coverage

CertificationStatus
CE (EMC) — CKEYS251201016Covered
FCC SDoCNot held for this model
RoHS 2.0Not held for this model
GB 4943.1-2022 — BDL260706S002Covered (series)
Battery type for this model is AGM deep-cycle or GEL — not the lithium chemistries used on other models. Confirm the intended battery before ordering. Full detail on the certifications page.

Related pages

Request a quotation