HE310-5000-F — 5000 W Low-Frequency Inverter
One line: An industrial-frequency inverter for the loads that punish high-frequency units — pumps, motors, compressors. 5000 W / 6300 VA, 48 V, with a no-load loss below half that of a same-power high-frequency unit.

Specifications — input
| Item | Value |
|---|---|
| Capacity | 6300 VA |
| Battery voltage (DC) | 48 V |
| Rated voltage | 220 VAC / 110 VAC |
| Voltage range | 154–264 VAC / 77–132 VAC |
| Frequency | 50–60 Hz auto-sensing |
| Input protection | Circuit breaker |
Specifications — output
| Item | Value |
|---|---|
| Power | 5000 W |
| Voltage | 220 VAC / 110 VAC |
| Frequency | 50/60 Hz |
| Waveform | Pure sine wave |
| Transfer time | <8 ms (AC to DC) / <8 ms (DC to AC) |
| Efficiency | >98% |
| Output protection | Circuit breaker |
Specifications — PV and battery
| Item | Value |
|---|---|
| Max PV array power | 6400 W (48 V) |
| MPPT input voltage range | 60–150 VDC |
| Max PV array open-circuit voltage | 150 VDC |
| Max solar charge current | 120 A |
| Battery type | AGM deep-cycle / GEL |
| Battery capacity | Up to 500 Ah |
| Battery voltage | 48 VDC |
| Battery charging voltage | 54.8 VDC |
| Charge current | 50 A |
| Max AC charge current | 104 A (default 83 A) / 52 A (default 42 A) |
Specifications — general
| Item | Value |
|---|---|
| Transfer time | ≤10 ms (UPS mode) / ≤20 ms (INV mode) |
| Load peak ratio | 3:1 (max) |
| Standby consumption | 12 V: 8 W / 24 V: 16 W / 48 V: 32 W |
| Operating temperature | −10 to 50 °C |
| Storage temperature | −15 to 45 °C |
| Relative humidity | up to 90%, non-condensing |
| Noise level | <45 dB |
| Dimensions | 545 × 400 × 175 mm |
| Packing dimensions | 657 × 504 × 257 mm |
| Net weight | 26.05 kg |
| Gross weight | 28.85 kg |
Why low frequency
A low-frequency inverter steps voltage through a large iron-core transformer before the output stage. The trade-off is honest:
| Low-frequency (this model) | High-frequency (HE200 / HE300) | |
|---|---|---|
| Size and weight | Large, heavy | Small, light |
| No-load loss | Below half of a same-power high-frequency unit | Higher |
| Inductive / surge load tolerance | Better | Adequate for ordinary loads |
| Load peak ratio | 3:1 | Model-dependent |
The 3:1 peak ratio is the number that matters for motor loads: a 1.5 kW pump with a 4.5 kW starting surge sits inside this unit's capability, where a high-frequency unit of similar rating may trip.
Low no-load loss matters on systems that idle for long periods — a unit that draws less when nothing is running wastes less energy from a finite battery bank.
Features
- Optional BMS communication.
- Optional PWM / MPPT solar charge controller.
- No-load loss below half that of an equivalent high-frequency unit.
- Pure sine wave output suited to varied loads.
- Output short-circuit protection.
- Multiple user-adjustable parameters.
- Large LED display — AC voltage and frequency, PV voltage and current, output voltage and frequency, battery voltage, load current.


Typical applications
- Agricultural irrigation pumps, where motor surge is the design constraint.
- Workshop machinery with inductive loads.
- Sites with poor or unstable grid supply, where the wide 154–264 VAC input window helps.
- Any installation where a low no-load loss over long idle periods matters.
Connections, monitoring and accessories
Terminal layout, system wiring, monitoring options and the accessories supplied with the unit.


Certification coverage
| Certification | Status |
|---|---|
| CE (EMC) — CKEYS251201016 | Covered |
| FCC SDoC | Not held for this model |
| RoHS 2.0 | Not held for this model |
| GB 4943.1-2022 — BDL260706S002 | Covered (series) |
Battery type for this model is AGM deep-cycle or GEL — not the lithium chemistries used on other models. Confirm the intended battery before ordering. Full detail on the certifications page.